Tripp Lite PDU Switched ATS 120V 15A 8 Outlet 1U (PDUMH15ATNET)

$832.99

Tripp Lite PDU Switched ATS 120V 15A 5-15R 8 Outlet 2 5-15P Horizontal 1URM – 2 12ft Cords, 1U Rack-Mount, TAA” (PDUMH15ATNET)

SKU: PDUMH15ATNET
A-Power Stock (In-Store Pick up & Shipping)

Description

Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED’s display primary or secondary power availability.

– 120V 15A Automatic Transfer Switch (ATS) / Switched PDU (Agency de-rated to 12A continuous)

– Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord

– Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface

– Digital display continuously reports total output power consumption in amps

– 8 switched NEMA 5-15R outlets

– 1U horizontal rackmount form factor; 14.5 in. / 36.8 cm depth

– Set of two 12 ft. / 3.6m NEMA 5-15P input cables support connection to separate PRIMARY and SECONDARY power sources

– ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable

– ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)

– Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported

– On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source

– Super-fast switchover between primary and secondary power sources occurs in 2-7 milliseconds

– DHCP/Manual configuration support; Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols

– Compatible with optional ENVIROSENSE temperature monitor

– Outlets are factory programmed for sequential turn-on at 250 millisecond intervals as the PDU is first energized

– Front panel LEDs confirm power availability on both input lines

– TAA Compliant Version Available – Order Tripp Lite PDUMH15ATNETAA

Additional information

Weight 7.72014 kg
PDU types

Switched

Certification

UL 60950-1, CSA, Class A, NOM

Operating altitude

0 – 3000 m

Storage temperature (T-T)

-15 – 50 °C

Dimensions (WxDxH)

444 x 368 x 44.4 mm

Nominal output voltage

100-127 V

AC input frequency

60 Hz

Maximum current

15 A

Nominal input voltage

100-127 V

RoHS compliance

Y

Rack capacity

1U

Cable length

3.66 m

Power plug

NEMA 5–15P

AC outlet types

NEMA 5–15R

AC outlets quantity

8 AC outlet(s)

Product colour

Black

Housing material

Metal

Mounting

Horizontal

I/O ports

60950 (USA, Canada), Class A, NOM (Mexico), RoHS